PFA In-Line Solvent Heater - ACCUHEAT

For heating Solvents such as IPA (Isopropyl alcohol), NMP, and much more. IMTEC introduces the high-purity PFA solvent inline heater.

This inline heater is designed to safely heat volatile flammable solvents while maintaining a high purity flow path. Equipped with multiple safety devices this inline heater is certified for operation within a Class I, Division II environment. Single pass or recirculating, this inline is ready to deliver stable fluid temperatures over a range of flow rates.


Teflon Solvent Inline heater Point of Use and Recirculating Diagram
Benefits

● Stainless Steel housing and metal core enables a grounded construction preventing spark generation

● All wiring shielded with conductive, grounded, PTFE conduit preventing spark generation

● Low flow N2 housing purge provides positive pressure inert environment preventing the possibility of flame or ignition

● Indirect heating, no immersed heater elements which can lead to shock or contamination

Features

● Class I, Division II Environment Compliant (Third Party Certified)

● Continuous internal flow path, no O-Rings or compression seals

● All wetted surfaces are high purity PFA

● Stainless Steel housing

● Maximized watt density for performance

● Zero maintenance required

● PFA fluid path, wide solvent compatibility

● Redundant Over-Temperature Devices

Available Wattages: 3.0 KW, 4.5 KW, 6.0 KW, 9.0 KW, 12.0 KW, 18.0 KW, Custom Wattage Available

Process Chemistries: IPA (Isopropyl alcohol), EKC (EKC265, EKC830, EKC270), Acetone, Ethanol, Toluene, MEK (methyl ethyl ketone), NMP, and much more.

Max. Operating Temp: 180 °C (solvent dependent)

Max. Pressure: 40PSI @ 180 °C 100PSI @ 25 °C

Voltages: 200-400VAC, single or 3 phase model dependent

Meets Requirments of: CE, Semi S2 & S3,

IEC – Class 1, Zone 2, Ex, pzc, T5 – IEC 60079.0 and 60079.2

EU – Class 1, Zone 2, EEx, pzc, Group IIA, IIB, and IIC, T5 - IEC 60079.0 and 60079.2

USA – Class 1, Division 2, Group B, C, and D, Pressurization Type Z, T5 – 100 degrees C) – NFPA 496

USA – Class 1, Zone 2, AEx, pzc, Group IIA, IIB, and IIC, T5 - IEC 60079.0 and 60079.2

ATEX – Group II, Equipment Category 3G, Zone 2